the_lvis_user_interface [2023/05/10 13:16] – [Editors] 2003:c8:4f17:8100:7dcc:cf8b:83b2:eeccthe_lvis_user_interface [2023/05/10 15:25] (current) – [Configuration bar] 2003:c8:4f17:8100:7dcc:cf8b:83b2:eecc
Line 362: Line 362:
    
 ==== Admin ==== ==== Admin ====
 +The Admin menu allows you to password-protect several LVis settings against unauthorized access. This includes the following functions:
 +
 +Change global settings
 +• Change of LVis [[global settings]]
 +
 +Change MCB settings
 +• [[Detector configuration]] (changes the hardware settings of the measuring chain)
 +
 +Change QA settings
 +• [[QA settings]] (tolerances and intervals, etc. specification for QA measurements)
 +
 +Delete a detector
 +• [[Delete detector]] (removes a detector from the list of available detectors) 
 +
 +Parameter sets: create, edit, delete, copy, import, load, save
 +• [[New parameter set]] (creates a new measurement parameters set for a detector)
 +• [[Delete parameter se]]t (removes a parameter set from the list of available parameter sets of the detector)
 +• [[Edit parameter set]] (changes predefined measurement and analysis parameters, unlocks input fields for the user)
 +• [[Copy parameter set]] (copies a complete measurement parameter set)
 +• I[[mport parameter set from existing]] .LVM file (applies settings of a .LVM measurement as new parameter set)
 +• [[Load parameter set]] (imports a parameter set, saved as a .LVP file, into a detector)
 +• [[Save parameter set]] (saves a parameter set as .LVP file)
 +
 +Reference sources: create, edit load, save
 +• [[New reference source]] (manual creation of a new calibration source)
 +• [[Load reference source]] (imports a reference source, saved as .LVS file)
 +• [[Save reference source]] (saves a reference source as .LVS file)
 +• [[Edit reference source]] (edits an already existing reference source)
 +
 +Change passwords
 +• [[Change password]] (changes the current administrator password)
 +• [[Set start password]] (changes the password to be entered when starting LVis)
 +
 +These changes can only be made by an administrator (or by any user doing so before the administrator password is set). Adding and removing password protection from LVis functions is as simple as clicking on the “padlock” icon beside a data entry field (the red padlock indicates a field that has been locked; a green padlock means the field is unlocked). 
 === Login and Logoff === === Login and Logoff ===
 +There are two options to unlock the application. Either you click on “
 +[[Admin]]“ in the [[menu bar]] and then click on “Login”, or you can click on the green “open padlock” icon (“[[Login]]”) on the[[tool bar]]
 +In both cases, you reach the login window, where password entry will be requested.
 +<WRAP todo>**IMAGE MISSING**</WRAP>
 +<WRAP todo>**IMAGE MISSING**</WRAP>
 + After you enter the password and confirm it with “OK”, the application will be unlocked. After the administrator has performed the requested settings, it is expedient to lock the program again to protect it against unauthorized changes. To log off, select “[[Logoff]]” from the Admin menu or click on the red “closed padlock” icon on the [[tool bar]].
 +<WRAP important>
 +**Important**\\
 +As soon as you set this password, you are logged in as the administrator
 +</WRAP>
 +<WRAP todo>**IMAGE MISSING**</WRAP>
 === Change Password === === Change Password ===
 +To change the administrator password, click on “Admin” -> “Change password” to open the following dialog.
 +<WRAP todo>**IMAGE MISSING**</WRAP>
 +Enter the current password first (if no old password exists, simply leave the field empty). Then enter the new password, confirm it by entering it a second time, and click on “OK” to apply it. Passwords are case-sensitive.
 +<WRAP todo>**IMAGE MISSING**</WRAP>
 +<WRAP important>
 +**Important**\\
 +As soon as you set this password, you are logged in as the administrator
 +</WRAP>
 + <WRAP important>
 +**Important**\\
 +Once a password has been set, it can be changed but not removed completely (i.e., there is no way to revert to the factory “unpassworded” condition). If you forget the password, contact your ORTEC representative or our Global Service Center for assistance.
 +</WRAP>
 === Set Start Password === === Set Start Password ===
 +LVis allows you to set a password to prevent program start by unauthorized users. If the wrong password is entered on startup, LVis automatically closes. Users who log in with this password do not have Administrator privileges, hence, cannot change any locked data fields or functions.
  
-==== LabJournal ====+<WRAP important> 
 +**Important**\\ 
 +This password is separate from the administrator password (even if you use the same character string for both passwords). Administrator-level users must know this password to start the program, and the administrator password to access locked program functions. Once a start password has been set, it can be changed but not removed completely (i.e., there is no way to revert to the factory “unpassworded” condition). If you forget the password, contact your ORTEC representative or our Global Service Center for assistance. 
 +</WRAP>
  
 +To set the start password, click on “Admin” -> “Set start password” on the menu bar.
 +
 +<WRAP todo>**IMAGE MISSING**</WRAP>
 + You reach the following dialog box:
 +
 +<WRAP todo>**IMAGE MISSING**</WRAP>
 + Enter the current password first (if no old password exists, simply leave the field empty). Then enter the new password, confirm it by entering it a second time, then click on “OK” to apply it. Passwords are case-sensitive.
 +
 +The next time the LVis program is started, the start password must be entered.
 +<WRAP important>
 +**Important**\\
 +If you forget the password, contact your ORTEC representative or our Global Service Center for assistance.
 +</WRAP>
 + 
 +
 + 
 +==== LabJournal ====
 +The LVis LabJournal is a log (a database) of all your measurements, their related sample and analysis information as well as the corresponding analysis results. The graphical interface of the LabJournal allows easy file filtering, data retrieval, [[archiving]] and Microsoft Excel [[reporting]] from data of multiple measurements.
 +<WRAP todo>**IMAGE MISSING**</WRAP>
 +The LVis menu bar gives you two options under “LabJournal”: “Start LabJournal” opens the LabJournal program and “Import measurements” creates a new or updates an existing LabJournal database with the data from all LVM files in your …\LVis database directory\Measurements directory.
 +It is important to note, that the LVis Labjournal database (LabJournal.mdb) is located in the Config folder of your LVis database directory. If this file does not exist, “Import measurements” will create the database for you and will go through all LVM files in your LVis database folder and will add their data into the LabJournal. 
 +<WRAP important>
 +**Important**\\
 +Depending on the number of LVis LVM files on your system the import of analyses into the LabJournal can take some time. LVis should not be interrupted during the import!
 +</WRAP>
 ==== Help ==== ==== Help ====
 +The “About LVis” screen provides software version information for this copy of LVis.
  
 +<WRAP todo>**IMAGE MISSING**</WRAP>
 ===== Configuration bar ===== ===== Configuration bar =====
 +The configuration sidebar, on the left side of the LVis application window, is the gateway to detector setup and operation. 
 +
 +This bar lists all measurement chains ([[detectors]]) and the  [[parameter sets]] defined for each. 
 +
 +The Reference Sources section of configuration bar gives you access to the [[reference source editor]], a convenient tool for managing the information on your calibration standards; and allows you to use the reference source entries to perform calibrations.
 +
 +In addition, it provides the [[Buffer]] (a virtual detector window) in which GammaVision can load .CHN spectrum files and analyze them using parameter sets.
 +
 +If any [[multi-detector configurations]] are defined, they are listed here.
 +
 +The [[Currently open]] section lists all currently open analysis and spectrum windows.
 +
 +In addition, you can right-click in the sidebar and create a [[backup copy of the entire, current LVis configuration]].
 +
 +
  